Reset procedure for the Brother DR2100 drum unit (photoconductor). This procedure will reset the drum counter back to zero and allow you to keep using your drum unit long after the Change Drum message appears. It will not fix any quality issues it will simply allow you to keep printing beyond the set life of the drum unit.

Free instructions below

HL PRINTER SERIES:

1.Remove the drum unit and toner cartridge. Wait 1 or 2  minutes.
2.Replace the drum unit and toner cartridge into printer.
3.The Drum LED continues to blink if the drum counter was not reset when you replaced the drum. We need to reset this now!
4.Open the front cover of the printer
5.Press and hold down Go button for about 4 seconds until all the LEDs light up.
6.Once all 4 LEDs are lit, release the Go button
7.Close the front cover.
8.Your drum is now reset.

MFC / DCP PRINTER SERIES

1.Remove the drum unit and toner cartridge. Wait 1 or 2 minutes.
2.Replace the drum unit and toner cartridge into printer.
3.The error message "Change Drum Soon/Drum end soon" will continue to appear if the drum counter was not reset when you replace the drum unit.
4.To clear this error message, you need to reset the drum counter as instructed below.
5.Make sure that the machine is turned on.
6.Press Options.

For MFC users: To confirm you are installing a new drum, press 1.  For DCP users  To confirm you are installing a new drum, press the Up Arrow key

7.When the LCD shows Accepted, close the front cover.
8.Your drum is now reset.

Resetting the drum unit will not improve print quality. It only resets your drum and allows you to continue to print. You decide when to replace the drum unit not the manufacturer!